FAQ >> How to choose parts of a Wired Nurse Calling & Intercom System

Hope to adopt the Nurse Calling and Intercom System in your hospital, but do not know how to choose the suitable and necessary parts? Either do not know how many parts are need? Here, we would like to give you some illustration and advice to tell you how to choose and confirm the quantity:

 

1, Nurse Calling and Intercom Host Machines:
We supply two models of Nurse Calling and Intercom Host Machines, as follow pictures show:

Host Machines are usually placed in the Nurse Station for nurses to call patients / to answer patients’ calling. Also, all setting-up of the system is done by nurses with the host machines;
Host Machine is a necessary part for the Nurse Calling and Intercom System;
Usually, there is one (for no more than 96 calling panels) or more (for more than 96 calling panels) Host Machine in each nurse station. So, the quantity of host machine is depended on nurse station quantity.

2, System Data Processors:
We supply one model of System Data Processor, as follow picture shows: 

System Data Processors are usually placed in the Nurse Station, too. It supplies DC electrical power to system, and process system data as a exchanger;
System Data Processor is a necessary part for the Nurse Calling and Intercom System;
One System Data Processor can control two Host Machines. So, quantity of system data processor is same or 1/2 of the quantity of host machines;

3, Patient’s Calling and Intercom Panels:
We supply several different models of Patient’s Calling and Intercom Panels as follow pictures show:

Patient’s Calling and Intercom Panels are usually installed above or beside patient’s beds for patients to call / talk with nurses;
Patient’s Calling and Intercom Panel is a necessary part for the Nurse Calling and Intercom System;
Usually, one patient’s calling and intercom panel for one patient. So, the quantity of patient’s calling and intercom panels is same as quantity of patient’s beds;

4, Electronic Patients List:
We supply several different models of Electronic Patients Lists as follow picture shows:

Electronic Patients Lists are usually placed in the Nurse Station to show patients simple information for nurses checking.
Electronic Patients List is an optional part for a Nurse Calling and Intercom System; Here, “Optional” means: this part has its’ special function for the system, but without it, the system works, too;
Usually, there is one (for no more than 60 patients) or more (for more than 60 patients) Electronic Patients List in each nurse station. So, the quantity of Electronic Patients List is depended on nurse station quantity;

5, Calling No. Display for Corridor
We supply one model of Calling No. Display for Corridor as follow picture shows:

Calling No. Displays are usually installed in the wards area corridor to show Calling Patient’s No. when somebody calling. It shows Time/Date when no calling;
Corridor Calling No. Display is an optional part for a Nurse Calling and Intercom System;
Usually, there is one (for a short corridor) or more (for a long corridor) Corridor Calling No. Display in each corridor. So, the quantity of Corridor Calling No. Displays is depended on wards area corridor quantity;

6. Outdoor Light Indicator:
We supply two models of Outdoor Light Alarm as follow pictures show:

Outdoor Light Indicators are usually installed outside the ward and above the door to alarm by lighting when somebody in that ward calling;
Outdoor Light Indicator is an optional part for a Nurse Calling and Intercom System;
One Outdoor Light Indicator for one ward. So quantity of Outdoor Light Indicators is same as ward room quantity;

7. Button Type Emergency Calling Panel:
We supply one model of Button Type Emergency Calling Panel as follow picture shows:

Button Type Emergency Calling Panels are usually installed in the washroom beside the toilet for patients to call nurses when any emergency;
Button Type Emergency Calling Panel is an optional part for a Nurse Calling and Intercom System;
Usually, there is one Button Type Emergency Calling Panel beside each toilet in the washroom. So, quantity of Button Type Emergency Calling Panels is same as Toilets quantity;

8, Pull-Cord Type Emergency Calling Panel:
We supply one model of Pull-Cord Type Emergency Calling Panel as follow picture shows:

Pull-Cord Type Emergency Calling Panels are usually installed in the washroom beside the shower for patient to call nurses when any emergency;
Pull-Cord Type Emergency Calling Panel is an optional part for a Nurse Calling and Intercom System;
Usually, there is one Pull-Cord Type Emergency Calling Panel beside each shower in the washroom. So, quantity of Pull-Cord Type Emergency Calling Panels is same as shower quantity.

Tel : +86 20 2988 6684
Fax : +86 20 2898 1384
Add: Room 301, Dongtai Business Centre, 1st.Dongping Avenue, Baiyun District, Guangzhou 510440, P.R.China

Chinese Deutsch Espanol Francais Italiano Portugues Japanese Korean Arabic Russian
  
Copyright © 2010-2020 GUANGZHOU C&H MEDICAL TECHNOLOGY CO., LTD. All Rights Reserved  sitemap  

Online service

info@ch-med.com sales@ch-med.com